Chemical-free disinfection
Uses ultraviolet light to sterilise or deactivate bacteria, viruses and other microorganisms without chemical dosing or water wastage
A high-intensity ultraviolet disinfection system available in 2 GPM and 6 GPM models for filtered cold water serving drinking, beverage, ice and foodservice applications.
Uses ultraviolet light to sterilise or deactivate bacteria, viruses and other microorganisms without chemical dosing or water wastage
A polished SUS304 chamber and quartz sleeve support UV transmission and hygienic operation.
Sound-and-light indication helps identify a UV lamp malfunction.
Small footprint and low power consumption support final-stage foodservice installations.
| Product Name | Pentair Everpure Ultraviolet Water Sterilizer | Application | Ultraviolet disinfection of filtered cold water for beverage, ice and foodservice applications. |
|---|---|
| Filtration Rating | Not applicable. UV treats microorganisms by light and does not provide particulate filtration. |
| Capacity | Treatment capacity depends on flow and the rated UV lamp life of 9,000 hours. |
| Flow Rate | PFB-002: 2 GPM, approximately 0.45 T/h. PFB-006: 6 GPM, approximately 1.36 T/h. |
| Dimensions | PFB-002: L1 360 mm, L2 260 mm, W 51 mm, H 67 mm. PFB-006: L1 564 mm, L2 454 mm, W 63.5 mm, H 90 mm. |
| Operating Pressure | Rated pressure up to 0.7 MPa; operate within the complete plumbing-system design limits. |
| Operating Temperature | Recommended source-water temperature: 2–40°C. |
| Connections | PFB-002 chamber: 1/2 inch NPT-F. PFB-006 chamber: 3/4 inch NPT-F. Horizontal or vertical installation accepted. |
| Certifications | No certification is explicitly listed on the current product information. Published warranty: one year from installation or 18 months from production, whichever occurs first. |
| Recommended For | Final-stage UV disinfection on suitable pre-filtered cold-water supplies. |
Aquainwent is positioned as importer and nationwide distributor in India.
Performance depends on flow, UV dose and suitable source-water conditions
One year from installation or 18 months from production, whichever occurs first.
Plan lamp replacement and quartz-sleeve inspection or cleaning around operating conditions.
A compact final disinfection barrier when the water is already filtered and the requirement is microbiological treatment without chemical dosing.
Water source, microbiological concern, flow demand and application points.
Confirm pre-filtration, pressure, temperature, port size and mounting.
Mount horizontally or vertically according to the approved technical instructions.
Replace the lamp and inspect or clean the quartz sleeve as required.
Adds UV disinfection without chemical dosing or water wastage.
Choose between 2 GPM and 6 GPM based on actual demand.
Lamp, sleeve and operating checks support dependable UV performance.
Share your source-water quality, required flow and application. Aquainwent will help verify the suitable UV model and upstream treatment.